Monitoring Software Compression Using the BCC show Command
117352-E Rev 00
C-5
show wcp stats error1
The
show wcp stats error1
command displays information about error
conditions for WCP compression on the connection.
The output includes the following information:
show wcp stats error2
The
show wcp stats error2
command displays information about error
conditions pertaining to WCP compression on the connection.
The output includes the following information:
CPC pkts Number of CPC packets transmitted (Tx) and received (Rx).
PPC pkts Number of PPC packets transmitted (Tx) and received (Rx).
Channel Number Number of the channel on which this virtual circuit is running.
Circuit Name Circuit name of the interface.
Vc Id Identification of the virtual circuit.
Anti-Expanded
Packets (Tx)
Number of anti-expanded packets transmitted.
Anti-Expanded
Packets (Rx)
Number of anti-expanded packets received.
Data Out of Sequence Number of instances registered of the data-out-of-sequence
condition.
Rexmit Out of
Sequence
Number of times that an acknowledgment was retransmitted out
of sequence.
Rexmit Time-Outs Number of timeout messages retransmitted.
Exceeded Ks Number of times that K was exceeded. (WCP maintains a
transmit history of data packets for a specified range called “K.” A
packet can be retransmitted if it remains in the range of packets
kept in the transmit history. If a packet is outside the range
specified by K, it cannot be retransmitted.)
Channel Number Number of the channel on which this virtual circuit is running.
Circuit Name Circuit name of the interface.