Avaya Configuring LLC Services Uživatelský manuál Strana 72

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 82
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 71
Configuring LLC Services
4-10 117357-A Rev. A
Parameter: Ack Timer for Xmt
Default: 1 s
Range: 1 to 15
Function: Specifies the amount of time, in seconds, during which the local LLC
expects to receive
An acknowledgment for one or more outstanding I-PDUs sent during
the timer window
A response PDU for an unnumbered command PDU sent during the
timer window
A response PDU with the F bit set
Instructions: Enter a valid value from 1 to 15.
The default value (1s) works with most environments, but may be too
small if the LLC connection is over Frame Relay, a source route network
with multiple hops, or if the endstation responds slowly to I-Frames.
Choose a value that is appropriate for the applications LLC2 supports.
MIB Object ID: 1.3.6.1.4.1.18.3.5.1.6.2.1.13
Zobrazit stránku 71