DDI MUX Installation Guide
The LEDs light under the following conditions:
Table 6 DDI MUX LEDs
LED
Description
TxD
(Transmit data)
The LED flashes at a rate equal to the number of zeros in the data received from the
DTE and transmitted over the network. The speed of the flashes is an indication of
the speed of the data sent over the network.
RxD
(Receive data)
The LED flashes at a rate equal to the number of zeros in the data received from the
network and transmitted to the DTE. The speed of the flashes is an indication of the
speed of the data sent over the network.
RTS
(Request to Send)
The LED lights when the DTE requests permission from the DDI MUX to send data.
CTS
(Clear to Send)
The LED lights when the DDI MUX is signaling the DTE that it has permission to
send data.
DCD
(Data Carrier Detect)
The LED lights when the Business Communications Manager is receiving a carrier
signal.
DSR
(Data Set Ready)
The LED lights when the DDI MUX is ready to communicate.
TM
(Test Mode)
The LED lights when the DDI MUX is signaling to the DTE that it detects a test
condition.
(Power)
On indicates that the DTM is receiving +5 volts.
(Status)
On indicates there is data communication between the DDI MUX and the MSC card.
In Service Flashing indicates that the T1 trunks are out of service because a loopback test is
running or the DDI MUX is initializing.
Loopback On indicates a continuity loopback test is running on the T1 link.
Receive Alarm On indicates a problem with the received digital transmission on the T1 link. This
half-duplex link does not work.
Receive Error On indicates a small error as a result of degraded digital transmission on the T1 link.
Possible causes are an ohmic connection, water ingress, or too long a loop.
Transmit Alarm On indicates the DDI MUX cannot transmit on the T1 link. The DDI MUX sends an
Alarm indication signal (AIS) to the terminating switch. This half-duplex link does not
work.
Transmit Error On indicates the DDI MUX is sending a remote alarm indication (RAI) carrier failure
alarm (CFA) to the terminating switch. If the Transmit Alarm is not on, this error
indicates a far-end or cable problem.