Event Messages for Routers and BNX Platforms
5-72
Entity Code/Event Code 80/20
Decimal Identifier 16797716
Severity: Info
Message: ISDN BRI <channel_no.>, DSL <ID_no.>, Interface reset has completed.
Meaning: Indicates the ISAC chip is functioning properly and has reset properly. You usually see this
message when the ISDN driver is coming up or going down.
Entity Code/Event Code 80/21
Decimal Identifier 16797717
Severity: Info
Message: ISDN BRI <channel_no.>, DSL <ID_no.>, Interface reset has failed to complete.
Meaning: Indicates the ISAC chip is not functioning properly and has not reset properly, therefore
there is a hardware problem.
Action: There is a possible problem with the ISDN BRI Net module. Replace the module.
Entity Code/Event Code 80/22
Decimal Identifier 16797718
Severity: Info
Message: ISDN BRI <channel_no.>, DSL <ID_no.>, Interface signal received, identifying input.
Meaning: Indicates the S/T interface has received a signal other than INFO 0, and has not yet
synchronized with the data pattern. This only occurs when the S/T interface is in the F3
(deactivated) state.
Entity Code/Event Code 80/36
Decimal Identifier 16797732
Severity: Info
Message: ISDN BRI <channel_no.>, DSL <ID_no.>, Interface has received Info State 0.
Meaning: Indicates that the S/T interface received INFO 0 frames from the network. This indicates
that the S/T interface was not receiving any signals from the network. You see this
message only if the S/T interface is in state F7 (activated) or state F8 (lost framing) and
you enabled the T4 timer.
Action: Check that the RJ45 is still plugged in to the S/T interface. If it is, then this may be a
spurious occurrence on the wire. If this message occurs frequently, check with the central
office about the quality of the line.