Editing Frame Relay Parameters
4-9
Parameter: Monitored Events
Default: 4
Range: 0 to 2,147,483,647
Function: Together with the value of the Error Threshold parameter, establishes a
criterion used to evaluate the quality of the router/Frame Relay network
connection. Refer to the description of the Error Threshold parameter for
more information.
Instructions: Enter the number of consecutive status exchanges you want the router to
monitor.
MIB Object ID: 1.3.6.1.4.1.18.3.5.9.9.1.1.13
Parameter: Multicast
Default: Disable
Options: Enable
| Disable
Function: Enables or disables support for Frame Relay multicast service.
Instructions: Set to Enable if your Frame Relay subscription service provides multicast
service, and if this Frame Relay interface should receive multicast
messages.
MIB Object ID: 1.3.6.1.4.1.18.3.5.9.9.1.1.16
Parameter: Congestion Control
Default: Disable
Options: Enable
| Disable
Function: Enables or disables congestion control on this interface.
Instructions: Set to Enable to activate congestion control. This value tells the router to
drop all outbound traffic destined for a PVC where congestion is
occurring until the congestion clears. The value of this parameter affects
all PVCs that you do not individually configure.
MIB Object ID: 1.3.6.1.4.1.18.3.5.9.9.1.1.22