If you press Return before entering a sufficient number of characters for the BCC
to recognize the name of the object or parameter you want to configure, the BCC
returns an error message.
Example:
box# e
ambiguous command name "e": enable eof error ethernet eval exit expr
The BCC returns a list of all the commands available in the current context that
start with the letter “e.” Choose one command from the list, and enter enough
characters for the BCC to recognize that command when you press Return.
You cannot abbreviate BCC instance identifiers.
Specifying Parameter Values
You must specify each parameter value in the form of a parameter-value pair. Each
pair is a command argument pertaining to the object named first in the command
line.
For example, the following command changes the BOFL timeout interval to 4
seconds on ethernet/1/1:
box#
ethernet/1/1 bofl-timeout 4
bofl-timeout 4
is the parameter-value pair.
Required, Derived, and Other Parameters
The BCC indicates when parameter values are required (you must supply a value)
or derived (the BCC supplies a value). For all other parameters, the BCC supplies
a default value that you can change.
Specifying Multiple Parameter-Value Pairs
You can specify parameter values as follows:
Enter an object name and one parameter-value pair per command line.
Enter an object name and multiple parameter-value pairs (each pair separated
by a space) on the same command line.