Avaya Configuring Dial Services Uživatelský manuál Strana 321

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 426
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 320
Dial Service Parameters
117353-A Rev. A A-51
Demand Circuit Group Parameters
Parameter: Pool ID
Path: Dialup > Demand Circuit Groups > Demand Circuit Groups > Add Group >
Enter a Demand Pool
Default: None
Options: 1 to 255
Function: Identifies the demand pool that you want the demand circuit group to use.
Instructions: Enter the ID number of an existing demand pool.
MIB Object ID: 1.3.6.1.4.1.18.3.5.1.4.5.1.6
Parameter: Number of Circuits
Path: Dialup > Demand Circuit Groups > Demand Circuit Groups > Add Group >
Enter a Demand Pool
Default: None
Options: Maximum number of lines in the line pool
Function: Indicates how many unnumbered circuits are in the demand circuit group.
Instructions: Enter a number that is less than or equal to the number of lines in the demand
pool associated with this circuit group.
MIB Object ID: 1.3.6.1.4.1.18.3.5.1.4.12.1.4