Dial Service Parameters
117353-A Rev. A A-67
Parameter: Error Threshold
Path: Demand Circuits: Dialup > Demand Circuits > FR Circuits > FR Demand
Circuits > Demand Intf. > FR Demand Interface List
Backup Circuits: Dialup > Backup Circuits > Frame Relay > FR Primary
Interface Definition > Backup Def. > FR Backup Interface
Default: 3
Options: 0 to 2,147,483,647
Function: Together with the value of the Monitored Events parameter, establishes a
criterion to evaluate the quality of the router/Frame Relay network connection.
If you accept the default values for both Error Threshold and Monitored Events,
three status exchange errors in a sequence of four attempted exchanges will
bring the connection down. With Error Threshold set to 5 and Monitored Events
set to 10, five status exchange errors in a continuous sequence of ten attempted
exchanges will bring the connection down.
After the network clears the connection, status exchanges continue, and the
router monitors line integrity. When the number of consecutive, successful
status exchanges is equal to the Error Threshold value, the router restores the
Frame Relay connection.
Error Threshold and Monitored Events are nonfunctional if you set Mgmnt Type
to DLCMI None.
Instructions: Enter the number of faulty status exchanges that will bring the connection
down.