Q00510064-01: VRRP
VRRP may fault during initialization due to a timing issue
between the dependant processes on the router.
===============================================================
BayRS Version 14.0.3.9 corrects the following problem:
===============================================================
Q00470890: RIP
When RIP is configured on an ATM PVC, the router will only send
2-3 update packets per second. As a result, it can take a
significant amount of time to update the entire routing table
on a large network.
================================================================
BayRS Version 14.0.3.8 corrects the following problems:
================================================================
Q00245641: TI_INIT
The TI_INIT process does not release memory on FRE4 and ARE
modules when the Serial Port ModemEnable attribute is enabled.
If many login requests are made, this could eventually cause an
out of memory fault on the router.
Q00391307-02: Radius
When Radius is enabled, if an invalid login attempt is made,
the router logs a message that an invalid radius access response
packet was received and disables the Radius server rather than
sending an access reject packet.
Q00413482: SNMP
When an SNMP get request packet is received with an incorrect
checksum and also has both the More bit and Do Not Fragment bit
set, the router may fault.
================================================================
BayRS Version 14.0.3.7 corrects the following problems:
================================================================
Q00043378-02: IP
The router will fault when one of the four serial interfaces
changes from a down state to an active state while BGP routes
are downloading to the router.
Q00075870: DLSw
When in a redundant path environment, a DLSw connection may be
left in an inconsistent connected state after the router attempts
and fails to make a connection.
Q00137521: IP traffic filter
Configuring IP user defined traffic filters where the user data
offset is greater than the size of the smallest IP packet that
the interface receives (such as an OSPF hello or RIP update)
will cause a fault on an ARE module.