Avaya Configuring Ethernet, FDDI, and Token Ring Services Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Sítě Avaya Configuring Ethernet, FDDI, and Token Ring Services. Avaya Configuring Ethernet, FDDI, and Token Ring Services User's Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 82
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
Part No. 117020-A Rev. A
May 1997
Router Software Version 11.02
Site Manager Software Version 5.02
Configuring Ethernet,
FDDI, and Token Ring
Services
Zobrazit stránku 0
1 2 3 4 5 6 ... 81 82

Shrnutí obsahu

Strany 1 - Services

Part No. 117020-A Rev. AMay 1997Router Software Version 11.02Site Manager Software Version 5.02 Configuring Ethernet, FDDI, and Token Ring Servic

Strany 3 - Bay Networks Software License

117020-A Rev. A xi Tables Table 1-1. Site Manager Abbreviations for Circuit Types ...1-3Table 1-2. Getting In

Strany 5 - Contents

117020-A Rev. A xiii About This Guide If you are responsible for configuring and managing Bay Networks ® routers, read this guide to learn about phy

Strany 6

Configuring Ethernet, FDDI, and Token Ring Servicesxiv 117020-A Rev. A Conventions bold text Indicates text that you need to enter, command names, an

Strany 7

About This Guide 117020-A Rev. A xv MIB management information baseMIC media interface connectorMII media-independent interfaceNBMA nonbroadcast mul

Strany 8

Configuring Ethernet, FDDI, and Token Ring Servicesxvi 117020-A Rev. A Bay Networks Customer Service You can purchase a support contract from your Ba

Strany 9

About This Guide 117020-A Rev. A xvii For More Information For information about Bay Networks and its products, visit the Bay Networks Worldwide Web

Strany 11 - 117020-A Rev. A

117020-A Rev. A 1-1 Chapter 1Getting Started This chapter describes how to access the physical and data link layer ( line ) services for configured L

Strany 12

ii 117020-A Rev. A 4401 Great America Parkway 8 Federal StreetSanta Clara, CA 95054 Billerica, MA 01821 Copyright © 1988–1997 Bay Networks, Inc. All

Strany 13 - About This Guide

Configuring Ethernet, FDDI, and Token Ring Services1-2 117020-A Rev. A Accessing Line Services with Site Manager To access the Site Manager windows t

Strany 14 - Acronyms

Getting Started 117020-A Rev. A 1-3 Figure 1-2. Circuit List Window 3. Select the circuit for which you want to edit line service parameters. Table

Strany 15

Configuring Ethernet, FDDI, and Token Ring Services1-4 117020-A Rev. A Figure 1-3. Circuit Definition Window 5. Select Lines > Edit Lines. The Edit

Strany 16 - How to Get Help

Getting Started 117020-A Rev. A 1-5 Figure 1-4. Edit Lines Window 6. Select the line you want to edit and click on Edit. Depending on the type of ci

Strany 18

117020-A Rev. A 2-1 Chapter 2Configuring Ethernet Services The following sections of this chapter describe how to edit physical layer parameters for

Strany 19 - Getting Started

Configuring Ethernet, FDDI, and Token Ring Services2-2 117020-A Rev. A Figure 2-2. Edit 100Mb/s CSMA/CD Parameters Window About Bay Networks Ethernet

Strany 20

Configuring Ethernet Services 117020-A Rev. A 2-3 100Base-T MediaEach Bay Networks 100Base-T router port provides two physical connectors for LAN me

Strany 21

Configuring Ethernet, FDDI, and Token Ring Services2-4 117020-A Rev. AEnabling or Disabling an Ethernet InterfaceThe router enables CSMA/CD services w

Strany 22

Configuring Ethernet Services117020-A Rev. A 2-5 Enabling or Disabling BofL MessagesWith BofL enabled, the router sends polling messages from this Eth

Strany 23 - Configuring WAN Line Services

117020-A Rev. A iii Bay Networks Software License This Software License shall govern the licensing of all software provided to licensee by Bay Netw

Strany 24

Configuring Ethernet, FDDI, and Token Ring Services2-6 117020-A Rev. AEither accept the default of five BofL Retries, or specify a value from 1 to 60.

Strany 25 - Configuring Ethernet Services

Configuring Ethernet Services117020-A Rev. A 2-7 Enabling or Disabling Hardware FilteringWhen you add an Ethernet circuit for a link or net module wit

Strany 26

Configuring Ethernet, FDDI, and Token Ring Services2-8 117020-A Rev. ASetting the 100Base-T Line SpeedTo match the physical wiring in your 100Base-T L

Strany 27 - 100Base-T Packet Size

Configuring Ethernet Services117020-A Rev. A 2-9 Configuring Automatic Line Speed NegotiationWhen you set the line speed to Automatic Negotiation, the

Strany 28 - Configuring BofL Messages

Configuring Ethernet, FDDI, and Token Ring Services2-10 117020-A Rev. AYou can set the advertised line speed to• 100Base-TX, half-duplex only• 100Base

Strany 29 - Setting BofL Retries

Configuring Ethernet Services117020-A Rev. A 2-11 Figure 2-5. Sample Auto Negotiation State Information WindowTable 2-2. 100-Mb/s Ethernet Auto Negoti

Strany 31 - Configuring Ethernet Services

117020-A Rev. A 3-1 Chapter 3Configuring FDDI ServicesThe following sections in this chapter describe how to edit physical and link layer parameters fo

Strany 32 - 2-8 117020-A Rev. A

Configuring Ethernet, FDDI, and Token Ring Services3-2 117020-A Rev. AFigure 3-1. Edit FDDI Parameters Window About Bay Networks FDDI MediaFiber Distr

Strany 33 - 117020-A Rev. A 2-9

Configuring FDDI Services117020-A Rev. A 3-3 Enabling or Disabling a FDDI InterfaceThe router enables FDDI line services when you add the interface. Y

Strany 34 - 2-10 117020-A Rev. A

iv 117020-A Rev. A Bay Networks Software License (continued) 9. Licensee shall not reverse assemble, reverse compile, or in any way reverse enginee

Strany 35

Configuring Ethernet, FDDI, and Token Ring Services3-4 117020-A Rev. AEnabling or Disabling Hardware FilteringWhen you add a FDDI circuit for a link m

Strany 36

Configuring FDDI Services117020-A Rev. A 3-5 To edit the SMT parameters for a FDDI line:1. Click on Expert at the Edit FDDI Parameters window (refer t

Strany 37 - Configuring FDDI Services

Configuring Ethernet, FDDI, and Token Ring Services3-6 117020-A Rev. AFigure 3-3. FDDI SMT Attributes WindowThe following sections describe how you ca

Strany 38 - About Bay Networks FDDI Media

Configuring FDDI Services117020-A Rev. A 3-7 Specifying the SMT Connection PolicyA FDDI station sets the corresponding policy for each of the connecti

Strany 39 - Setting the BofL Interval

Configuring Ethernet, FDDI, and Token Ring Services3-8 117020-A Rev. ATable 3-1 lists the powers and the bits for each policy range.Figure 3-4 shows t

Strany 40 - Editing FDDI SMT Attributes

Configuring FDDI Services117020-A Rev. A 3-9 Specifying the Neighbor Notification IntervalNeighbor information frames (NIFs) identify the upstream and

Strany 41 - 117020-A Rev. A 3-5

Configuring Ethernet, FDDI, and Token Ring Services3-10 117020-A Rev. AYou can disable or enable SRFs for this circuit. We recommend enabling SRFs to

Strany 42 - 3-6 117020-A Rev. A

Configuring FDDI Services117020-A Rev. A 3-11 Editing MAC AttributesThe FDDI Media Access Control (MAC) standard defines the timed-token protocol, fram

Strany 43 - Configuring FDDI Services

Configuring Ethernet, FDDI, and Token Ring Services3-12 117020-A Rev. AEditing FDDI Path AttributesFDDI nodes exchange frames using the Timed-Token Pr

Strany 44 - 3-8 117020-A Rev. A

Configuring FDDI Services117020-A Rev. A 3-13 Figure 3-7. FDDI Path Attributes WindowYou can set FDDI path attributes by• Specifying the Minimum TVX•

Strany 45

117020-A Rev. A v Contents About This Guide Before You Begin ...

Strany 46 - Entering User Data

Configuring Ethernet, FDDI, and Token Ring Services3-14 117020-A Rev. ASpecifying the Maximum TTRTThe Maximum TTRT value must be • Greater than or equ

Strany 47 - Editing MAC Attributes

Configuring FDDI Services117020-A Rev. A 3-15 Editing FDDI Port AttributesPort attributes report the connection capabilities of a FDDI port, including

Strany 48 - Editing FDDI Path Attributes

Configuring Ethernet, FDDI, and Token Ring Services3-16 117020-A Rev. ASpecifying the LER CutoffThe LER cutoff is an estimate at which a link connecti

Strany 49 - Specifying the Minimum TVX

117020-A Rev. A 4-1 Chapter 4Configuring Token Ring ServicesThe following sections in this chapter describe how to edit physical and link layer paramet

Strany 50 - Specifying the Requested TTRT

Configuring Ethernet, FDDI, and Token Ring Services4-2 117020-A Rev. AAbout Bay Networks Token Ring MediaToken ring is a 4- or 16-Mb/s token-passing,

Strany 51 - Editing FDDI Port Attributes

Configuring Token Ring Services117020-A Rev. A 4-3 You can set the source for MAC addresses on a token ring interface to• BOXWIDE -- The interface use

Strany 53 - Chapter 4

117020-A Rev. A A-1 Appendix ASite Manager Line Services ParametersThis appendix contains reference information on Site Manager Line Service parameter

Strany 54 - 4-2 117020-A Rev. A

Configuring Ethernet, FDDI, and Token Ring ServicesA-2 117020-A Rev. AParameter: BofL EnablePath: Configuration Manager > XCVR Connector > Edit L

Strany 55 - Specifying the Ring Speed

Site Manager Line Services Parameters117020-A Rev. A A-3 Parameter: Hardware FilterPath: Configuration Manager > XCVR Connector (10Base-T only) >

Strany 56

vi 117020-A Rev. A Chapter 3Configuring FDDI Services About Bay Networks FDDI Media ...

Strany 57 - Appendix A

Configuring Ethernet, FDDI, and Token Ring ServicesA-4 117020-A Rev. AParameter: BofL Timeout DivisorPath: Configuration Manager > XCVR Connector &g

Strany 58 -

Site Manager Line Services Parameters117020-A Rev. A A-5 Parameter: Interface Line SpeedPath: Configuration Manager > XCVR Connector (100Base-T only

Strany 59

Configuring Ethernet, FDDI, and Token Ring ServicesA-6 117020-A Rev. AFDDI Line ParametersParameter: Enable Path: Configuration Manager > FDDI Conne

Strany 60 - A-4 117020-A Rev. A

Site Manager Line Services Parameters117020-A Rev. A A-7 Parameter: BofL TimeoutPath: Configuration Manager > FDDI Connector > Edit Line > Edi

Strany 61 -

Configuring Ethernet, FDDI, and Token Ring ServicesA-8 117020-A Rev. AParameter: Connection PolicyPath: Configuration Manager > FDDI Connector >

Strany 62 - FDDI Line Parameters

Site Manager Line Services Parameters117020-A Rev. A A-9 Parameter: User DataPath: Configuration Manager > FDDI Connector > Edit Line > Edit F

Strany 63

Configuring Ethernet, FDDI, and Token Ring ServicesA-10 117020-A Rev. AParameter: Duplicate Address ProtocolPath: Configuration Manager > FDDI Conne

Strany 64 - A-8 117020-A Rev. A

Site Manager Line Services Parameters117020-A Rev. A A-11 Parameter: Tvx Lower Bound (ms)Path: Configuration Manager > FDDI Connector > Edit Line

Strany 65

Configuring Ethernet, FDDI, and Token Ring ServicesA-12 117020-A Rev. AParameter: Requested TTRT (ms)Path: Configuration Manager > FDDI Connector &g

Strany 66

Site Manager Line Services Parameters117020-A Rev. A A-13 Token Ring Line ParametersParameter: Enable Path: Configuration Manager > TOKEN Connector

Strany 67 - 117020-A Rev. A A-11

117020-A Rev. A vii Appendix ASite Manager Line Services Parameters CSMA/CD Line Parameters ...

Strany 68 - A-12 117020-A Rev. A

Configuring Ethernet, FDDI, and Token Ring ServicesA-14 117020-A Rev. AParameter: MAC Address SelectPath: Configuration Manager > TOKEN Connector &g

Strany 69 - Token Ring Line Parameters

Site Manager Line Services Parameters117020-A Rev. A A-15 Parameter: Early Token ReleasePath: Configuration Manager > TOKEN Connector > Edit Line

Strany 71

117020-A Rev. A B-1 Appendix BDefault Line Parameter SettingsTables B-1 through B-7 list the default settings for LAN line attribute parameters, in th

Strany 72

Configuring Ethernet, FDDI, and Token Ring ServicesB-2 117020-A Rev. AFDDI Line ParametersTable B-2. FDDI Line ParametersParameter Default Enable Enab

Strany 73 - Appendix B

Default Line Parameter Settings117020-A Rev. A B-3 Token Ring Line ParametersTable B-5. FDDI Path Attribute ParametersParameter DefaultTvx Lower Bound

Strany 75

117020-A Rev. A Glossary-1 GlossaryAttributeSee parameter. Properties or functional aspects of a configurable MIB object. ChannelThe multiplexed signa

Strany 77 - Glossary

117020-A Rev. A Index-1 Symbols100Base-T. See Ethernet10Base-T. See EthernetAaccessing line service parameters, 1-2attribute, defined, Glossary-1BBay N

Strany 79

Configuring Ethernet, FDDI, and Token Ring ServicesIndex-2 117020-A Rev. AFFDDIdefault parameters, B-2MAC Attributes window, 3-11MAC LLC, 3-11overview

Strany 80

Index117020-A Rev. A Index-3 MMAC address, token ringoverride, 4-2source, 4-2Maximum TTRT, FDDI, 3-14mediaEthernet, 2-2FDDI, 3-2token ring, 4-2Minimum

Strany 82

117020-A Rev. A ix Figures Figure 1-1. Configuration Manager Window ................1-2Figure 1-2. Circ

Komentáře k této Příručce

Žádné komentáře