Site Manager Line Services Parameters
117020-A Rev. A A-11
Parameter: Tvx Lower Bound (ms)
Path: Configuration Manager > FDDI Connector > Edit Line > Edit FDDI
Parameters > Expert > Path Attributes > FDDI Path Attributes
Default: 2.5 milliseconds (ms)
Options: The value must be greater than zero and less than the value of Requested TTRT.
If the value of Requested TTRT is greater than 5.2 ms, set this parameter to a
value less than or equal to 5.2 ms. For example, if the value of Requested TTRT
is 165 ms, the value for Tvx Lower Bound must be less than or equal to 5.2 ms.
Function: Specifies the minimum time value of the Valid Transmission Timer (TVX).
Instructions: Accept the default value of 2.5 milliseconds or specify a new value less than or
equal to 5.2 milliseconds and less than the value of Requested TTRT.
MIB Object ID: 1.3.6.1.4.1.18.3.4.15.3.3.1.5
Parameter: T_Max Lower Bound (ms)
Path: Configuration Manager > FDDI Connector > Edit Line > Edit FDDI
Parameters > Expert > Path Attributes > FDDI Path Attributes
Default: 165 milliseconds (ms)
Options: 10 to 1336.9344 ms
Function: Allows you to specify the maximum time value of TTRT. The value must be
greater than or equal to 10 ms, greater than or equal to the value of the
Requested TTRT (ms) parameter, and less than or equal to 1336.9344 ms.
Instructions: Accept the default value of 165 ms, or specify a new value less than or equal to
1336.9344 ms and greater than or equal to the value of the Requested TTRT
(ms) parameter.
MIB Object ID: 1.3.6.1.4.1.18.3.4.15.3.3.1.6