Configuring Frame Relay Services
3-14
117376-C Rev. 00
Using Site Manager
Adding PVCs to Service Records
You can use either the BCC or Site Manager to add PVCs to already existing
service records.
Using the BCC
You can add one or more PVCs at a time. To add one PVC:
1.
Navigate to the service record to which you want to add PVCs.
For example:
box; serial/1/2; frame-relay/1/2; service/boston
2.
Enter the
pvc
command and a DLCI number in this format:
pvc <DLCI number>
For example, the following command line creates a PVC with a DLCI of 20:
service/boston# pvc 20
pvc/3/2/20#
Site Manager Procedure
You do this System responds
1. In the Configuration Manager window,
click on a port configured for frame relay.
The Edit Connector window opens.
2. Click on
Edit Circuit
. The Frame Relay Circuit Definition
window opens.
3. Click on
Services
. The Frame Relay Service List window
opens.
4. Click on the service record entry.
5. Click on
Delete
. Site Manager removes the service record
entry from the Frame Relay Service List
window.
Zobrazit stránku 83