Setting Inactivity Values for SVCs
You can control how and when the router disconnects SVCs according to values
that you configure for amount of time and the direction that data is flowing. You
can set values for a service record or for individual SVCs.
You can use either the BCC or Site Manager to set inactivity values for SVCs.
Using the BCC
You can use the BCC to set values for a service record or for individual SVCs. You
set both the SVC’s inactivity timer and direction.
Service Record Inactivity Values
To set inactivity values for a service record, navigate to the prompt for the service
record you want to modify (for example,
box; serial/3/2; frame-relay/3/2;
service/8.0.32
) and enter:
svc-inactivity-timer
<integer>
integer
is the length of time, in seconds, before the SVC terminates if there is no
data activity in the direction specified in the
svc-inactivity-direction
parameter.
6. Set the following parameters:
• Signaling Control
• Max SVCs
• T303, Setup Message Timer
• T305, Disconnect Timer
• T308, Release Timer
• T310, Call Proceding Timer
• T322, Status Enq Retry Timer
• N322, Status Enq Retry Max
Click on
Help
or see the parameter
descriptions beginning on page A-18.
7. Click on
OK
. You return to the Frame Relay Interface
List window.
8. Click on
Done
. You return to the Configuration Manager
window.
Site Manager Procedure
(continued)
You do this System responds