Configuring WAN Line Services
8-2
117345-B Rev. 00
Configuring an FT1 Port
To enable FT1 services, you must complete the following steps. For instructions,
see the sections that follow.
1.
Select the port application.
2.
Set the clock parameters.
3.
Accept or customize the FT1 default port configuration.
To complete the configuration, you must also configure a non-PRI logical line.
Follow the instructions in the section on page 8-12
.
Selecting the Port Application
You configure an FT1 interface (port) using the lines for ISDN Primary Rate
Interface (PRI) permanent circuit (non-PRI) applications.
For FT1 ports, the default port application mode must be NONPRI. This indicates
that all of the lines have a permanent circuit number and are for leased lines, frame
relay, or permanent connections for other non-ISDN PRI applications.
To select the port application:
Site Manager Procedure
You do this System responds
1. In the Configuration Manager window,
click on an unconfigured FT1 connector.
The Port Application window opens
(Figure 8-1)
.
2. Set the Port Application Mode parameter
to
NONPRI
. For information on this
parameter, click on
Help
or see
page A-43
.
3. Click on
OK
. A window containing the clock
parameters opens (Figure 8-2)
.