Troubleshooting Routers
B-6
If you want to copy packets from more than one circuit, and the circuits are on
different I/O modules, add the hexadecimal values for the associated slots listed in
T
able B-1, and use the sum as the slot mask.
Example
Capture packets from the I/O modules inserted into Slots 3, 4, 8, and 10 as
follows:
1. Add the associated slot masks as follows:
2. Enter the sum in the set command as follows:
set wfProtocols.26.0 0x31400000;commit
Creating an Instance of Packet Capture
To create a Packet Capture record associated with a circuit or channel from which
you want to copy packets, you reference the circuit’s line number. A line number
is a unique number used to identify a circuit. Site Manager creates a line number
each time you add a circuit to the router’s configuration.
When you create a Packet Capture record, it creates a set of default parameter
values associated with the line number and stores them in the MIB. The standard
MIB term for this type of record is an “instance.”
Refer to the instructions in the section that applies to you:
•“Cr
eating an Instance for MCT1”
•“Cr
eating an Instance for Other Media”
Creating an Instance for MCT1
MCT1 uses logical lines within a physical connector. Each MCT1 line number
represents a logical line.
Slot 3
Slot 4
Slot 8
Slot 10
0x20000000
0x10000000
0x01000000
0x00400000
0x31400000