Installing Synchronous Net Modules in an ASN Platform
Cabling Requirements for the Net Modules10 BNX Software Version <x.x> Test Part Number
V.28 Compliance
V.28 compliance for the Dual Sync net module requires a
44-pin D-Sub to V.28 cable, Order No. 7837 (Table A-7 and Figure A-5).
V.28 compliance for the Quad Sync net module requires a 50-pin to V.28 cable,
Order No. AA0018023 (Table A-8 and Figure A-6).
Table A-7. Pin-to-Pin Connections for the 44-Pin D-Sub to V.28 Cable
(Order No. 7837)
Bay Networks Termination Remote Termination
Signal Pin to Pin Signal
Frame Ground 1 1 Frame Ground
Send Data+ 2 2 Send Data
Receive Data+ 3 3 Receive Data
Request to Send+ 4 4 Request to Send
Clear to Send+ 5 5 Clear to Send
Data Set Ready+ 6 6 Data Set Ready
Data Terminal Ready+ 8 20 Data Terminal Ready
Data Carrier Detect+ 9 8 Data Carrier Detect
Send Timing+ 10 15 Send Timing
Receive Timing+ 11 17 Receive Timing
Transmitter Signal Element Timing+ 12 24 Transmitter Signal Element Timing
Signal Ground 7 7 Signal Ground
Internal Connections
Pin 7 > 19 > 20 > 23
Pin 13 > 28
Pin 14 > 29
Komentáře k této Příručce