Configuring ATM Services
4-24
303514-A Rev. 00
Using Site Manager
To change the number of times the circuit can retransmit STATUS ENQUIRY
messages, complete the following tasks:
Disabling and Reenabling Restarts
By default, signaling sends restart messages automatically when a link comes up
from being in a down state. However, you can specify whether or not you want
signaling to send these restarts messages.
To disable automatic restart messages, navigate to the signaling prompt (for
example,
box; atm/11/1; signaling/11/1
) and enter:
send-restart disabled
For example, the following command disables restart messages on the ATM
connector:
signaling/11/1# send-restart disabled
signaling/11/1#
Site Manager Procedure
You do this System responds
1. In the Confi
g
uration Mana
g
er window,
click on the ATM interface (
ATM1
) that you
want to modify.
The Edit ATM Connector window opens.
2. Click on
Signaling Attributes
.The ATM Si
g
nalin
g
Parameters window
opens.
3. Set the
Num Stat Enquiries ReXmitted
parameter. Click on
Help
or see the
parameter description on pa
g
eA-45.
4. Click on
Done
. You return to the Edit ATM Connector
window.
5. Click on
Done
. You return to the Confi
g
uration Mana
g
er
window.