Customizing Signaling
303514-A Rev. 00
4-63
Using the BCC
To change the maximum connection control value, navigate to the SSCOP prompt
(for example,
box; atm/11/1; signaling/11/1; sscop/11/1
) and enter:
connect-control-maximum
integer
integer is the count value that you want the controller to use.
For example, the following command changes the maximum connection control
value to 6:
sscop/11/1# connect-control-maximum 6
sscop/11/1#
Using Site Manager
To change the maximum connection control value, complete the following tasks:
Site Manager Procedure
You do this System responds
1. In the Confi
g
uration Mana
g
er window,
click on the ATM interface (
ATM1
) that you
want to modify.
The Edit ATM Connector window opens.
2. Click on
Signaling AAL (SAAL)
.The ATM Si
g
nalin
g
AAL Records List
window opens.
3. Set the
Max Connection Control
parameter. Click on
Help
or see the
parameter description on pa
g
eA-56.
4. Click on
Done
. You return to the Edit ATM Connector
window.
5. Click on
Done
. You return to the Confi
g
uration Mana
g
er
window.