Customizing ISDN Lines
308621-14.00 Rev 00
11-11
Using Site Manager
To enable the use of an information element:
Configuring X.25 over a D Channel (BRI Only)
Using the BCC or Site Manager, you can configure X.25 over a D channel. This
feature is only for NET3 switch types in Germany and France.
To reduce the cost of connecting to an X.25 network, you can send X.25 packets
over an ISDN D channel instead of sending them over leased lines. To use the D
channel for X.25 packet transmission, the baud rate must be a maximum of
9600 b/s so that data is not lost. For more information about this feature, see
“X.25 Service over an ISDN D Channel (BRI Only)” on page 5-18.
You should have already created BRI service according to the instructions in
Chapter 2, “Starting Dial Services Using Site Manager” or Chapter 3, “Starting
Dial Services Using the BCC.” To enable this feature, go to one of the following
sections.
Site Manager Procedure
You do this System responds
1. In the Configuration Manager window,
choose
Dialup
.
The Dialup menu opens.
2. Choose
Edit Switch Parameters
. The ISDN Configured Switches window
opens.
3. Set the
Sending Complete IE
parameter
to
Enable
. Click on
Help
or see the
parameter description on page A-22.
4. Click on
Done
. You return to the Configuration Manager
window.
Caution:
If you enable or disable this feature dynamically, the router
disconnects all existing calls across the B channels while the ISDN software
makes the necessary changes. After the changes are complete, the software
restarts and you can make calls again.