Configuring and Customizing IGMP
303527-A Rev. 00
3-15
Specifying a Query Rate
By default, IGMP sends a group membership query on the interface every 120
seconds.
Specifying zero disables queries only. The router still forwards multicast
datagrams on this circuit.
You can use the BCC or Site Manager to disable queries or specify a query rate
from 0 to 4096 seconds.
Using the BCC
Navigate the IGMP prompt for the interface and enter:
query-rate
rate
rate is the number of seconds from 0 (disabling queries) to 4096.
For example, the following command specifies a query rate of 300 seconds:
igmp/2.2.2.2/3# query-rate 300
igmp/2.2.2.2/3#
Note:
If another IGMP router on this network has taken on the query role, this
router will not send out queries unless it has not heard of any queries within
the number of seconds specified by the Designated Router Timeout parameter.