Avaya Media Processing Server Series Alarm Reference Manual (Software Release 2.1) Uživatelský manuál Strana 436

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 452
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 435
NCD Alarms
The NCD alarms display the alarm/diagnostics messages sent from the Network
Interface Controller (NIC) and the redundant backup controller.
NCD 10004
NIC Loss of Reference Clock A to PLL
There is no longer a redundant reference clock (clock A) available for the
Phase Locked Loop. See “NIC Phase Lock Loop (PLL)” on page 441.
NIC Loss of Reference Clock B to PLL
There is no longer a redundant reference clock (clock B) available for the
Phase Locked Loop. See “NIC Phase Lock Loop (PLL)” on page 441.
NIC_PLL No Reference Clock Available for PLL. Cannot
perform inter-TMS bridging
There is no longer any reference clock available (either A or B) for the Phase
Locked Loop. See “NIC Phase Lock Loop (PLL)” on page 441.
NIC_Monitor Detected failure on Secondary NIC
The Primary NIC has lost connection with the secondary NIC. See “NIC
Redundancy” on page 441.
NIC Loss of data integrity on ATM fiber
There is a failure on one of the fiber connections. This can affect inter-chassis
bridging and PCM audio functions. See “NIC ATM” on page 441.
Over Temperature Condition exists on a NIC
The NIC hardware is no longer in the normal operating temperature range.
See “Temperature” on page 442.
The following messages indicate that the previous error conditions are clearing/have
cleared.
NIC_PLL Reference Clock A is available to PLL. Inter-TMS
bridging can now be performed
NIC_PLL Reference Clock B is available to PLL. Inter-TMS
bridging can now be performed
NIC Clearing Loss of all Reference Clocks