Editing APPN Parameters
308963-14.00 Rev 00
3-25
Parameter: Max Receive BTU Size
Default: 2057
Range: 256 to 4105
Function: Specifies the maximum Basic Transmission Unit (BTU) size that this
network node can receive. Each link station determines its own maximum
BTU size based on local node definitions and exchange identification
(XID) information received from the interface and the adjacent link
station.
Instructions: Enter a number in the range 256 to 4105 that the node can handle. The
minimum setting for HPR links is 768.
MIB Object ID: 1.3.6.1.4.1.18.3.5.14.1.3.1.9
Parameter: Max Send BTU Size
Default: 2057
Range: 256 to 4105
Function: Specifies the maximum Basic Transmission Unit (BTU) size that can be
sent over this port. Each link station determines its own maximum send
BTU size based on local node definitions and exchange identification
(XID) information received from the interface and the adjacent link
station.
Instructions: Enter a number in the range 256 to 4105. For Ethernet networks, the
maximum send BTU size should be less than or equal to 1500. For
synchronous media, the maximum send BTU size should be less than or
equal to the synchronous maximum transmission unit. The minimum
setting for HPR links is 768.
MIB Object ID: 1.3.6.1.4.1.18.3.5.14.1.3.1.24