Configuring MCE1 and MCT1 Interfaces
114078 Rev. A 6-13
Setting the Primary Clock Source (QMCT1)
You can specify the primary source for timing signals:
Select Internal to use the clock chip on the MCT1 module.
Select Port 1 Ext Loop to use the signal coming in from Port 1.
Select Port 2 Ext Loop to use the signal coming in from Port 2.
Select Port 3 Ext Loop to use the signal coming in from Port 3.
Select Port 4 Ext Loop to use the signal coming in from Port 4.
Select Auxiliary Ext to use an external source via BNC connectors.
Setting the Secondary Clock Source (QMCT1)
You can specify a backup source for timing signals:
Select Internal to use the clock chip on the link or net module.
Select Port 1 Ext Loop to use the signal coming in from Port 1.
Select Port 2 Ext Loop to use the signal coming in from Port 2.
Select Port 3 Ext Loop to use the signal coming in from Port 3.
Select Port 4 Ext Loop to use the signal coming in from Port 4.
Select Auxiliary Ext to use an external source via BNC connectors.
Site Manager: Primary Clock parameter: page A-54
Site Manager: Secondary Clock parameter: page A-54