Avaya Configuring MPLS Services Uživatelský manuál Strana 42

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 92
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 41
Configuring MPLS Services
3-6
305754-A Rev 00
Specifying a Remote TCP Port
The remote TCP port number specifies the remote TCP port of the label-switching
router (LSR) that the label edge router (LER) uses to establish the TCP
connection.
Accept the default, 8192, or enter a TCP port number from 1 to 65,535.
To change the remote TCP port number, complete the following tasks:
Site Manager Procedure
You do this System responds
1. In the Configuration Manager window,
click on the ATM interface (
ATM1
) that you
want to modify.
The Select Connection Type window
opens.
2. Click on
MPLS
. The Edit MPLS Connector window opens.
3. Click on
LDP
. The LDP Session Records List window
opens.
4. Set the
Remote TCP Port
parameter.
Click on
Help
or see the parameter
description on page A-4.
5. Click on
Done
. You return to the Edit MPLS Connector
window.
6. Click on
Done
. You return to the Select Connection Type
window.
7. Click on
Done
. You return to the Configuration Manager
window.
Zobrazit stránku 41
1 2 ... 37 38 39 40 41 42 43 44 45 46 47 ... 91 92

Komentáře k této Příručce

Žádné komentáře