Table 3-1. Functions of the Token Ring Link Module LEDs
LED Function
RCVR Indicates data is being received across the Token Ring connection.
NSRT Indicates the node is inserted into the Token Ring connection.
WFAIL Indicates a wire fault on either receive or transmit.
FAIL Indicates one of the following conditions:
• Diagnostic testing is in progress. Diagnostic testing occurs when you cold-start the
module. You cold-start the module when you cycle power, issue the diags command
from the Technician Interface, or hot-swap the link module. This LED blinks three
times and turns off when the diagnostic testing terminates successfully.
• Power-up diagnostic testing failed and the link module is waiting for an automatic
attempt to reinitiate diagnostic testing. If the FAIL LED turns on again, call the Bay
Networks Technical Response Center.
• A catastrophic failure due to a hardware problem on the link module occurred and
the link module is waiting for an automatic attempt to reinitiate diagnostic testing. If
the FAIL LED turns on again, call the Bay Networks Technical Response Center.