Sample Display - show csmacd receive
CSMACD Module Receive Errors:
-----------------------------
Internal
Receive MAC
Checksum Alignment Overflow Frames Symbol Receive
Slot Conn Circuit Errors Errors Errors Too Long Errors Errors
---- ---- -------- -------- --------- -------- -------- -------- --------
2 1 E21 0 0 0 0 0 0
5 1 E51 0 0 0 0 0 0
5 2 E52 0 0 0 0 0 0
3 entries in table.
Slot Slot identifier; ranges vary according to router model.
Conn Connector’s instance identifier; ranges vary according to router
model and Ethernet module. For routers other than ASN, indicates
the physical connector number on the slot.
Circuit Name of the circuit associated with this line.
Checksum Errors Number of frames received with a CRC error.
Alignment Errors Number of frames received that did not contain an integral number
of octets. Normally a frame alignment error also causes a checksum
error on the frame.
Overflow Errors Number of overflow errors received on this line in which the device
FIFO buffer overflowed before obtaining the next DMA cycle.
Frames Too Long Number of frames received that exceed 1518 octets.
Receive Symbol Errors Number of errors in hardware MLT3 encoding. Indicates a
problem. Only relevant on 100 Mb/s lines.
Internal MAC Receive Errors Number of frames containing less than 64 octets (
runt packets
).