Using Technician Interface Scripts
2-674
303560-A Rev 00
receive errors [circuit
<circuit name>
]
Displays receive errors for all circuits or for a specific circuit. The table includes the
following information:
Sample Display - show sync receive
SYNC Module Receive Errors:
---------------------------
Bad Runt Frame Frames Overflow
Slot Conn Circuit Frames Frames Rejects Too Long Frames
---- ---- ------- --------- --------- --------- --------- ---------
5 1 S51 0 7 0 0 0
5 2 S52 1 1 0 0 0
2 entries in table.
Slot Slot identifier; ranges from 1 to 14.
Conn Connector identifier; ranges from 1 to 4.
Circuit Name of the circuit associated with this line.
Bad Frames Number of bad receive frames, caused by Frame Check Sequence
(FCS) errors or nonoctet aligned errors.
Runt Frames Number of runt frames received on this line.
Frame Rejects Number of frame reject errors received on this line.
Frames Too Long Number of frames received on this line that exceed the MTU.
Overflow Frames Number of overflow errors received on this line in which the
device’s FIFO buffer overflowed before obtaining the next DMA
cycle. No buffer resources are available.