Sample Display - show ds1e1 timeslots circuit Boston
DS1E1 Timeslot Assignment:
--------------------------
|
----------Timeslots----------
|
Log 1111111111222222222233
Slot Conn Line Circuit 1234567890123456789012345678901
---- ---- ---- ---------- -------------------------------
2 1 1 Boston X__X________________X___
4 1 1 Boston XXXXXXX_________________
Found 1 match out of 24 entries in table.
transmit errors
[
circuit
<circuit name>
]
Displays statistical information about transmission errors for all circuits or for a specific
circuit. The table includes the following information:
Slot Slot identifier.
Conn Connector identifier.
Log Line Logical line number for this line.
Circuit Name of the circuit associated with this line.
Underflow Frames Number of retransmission underflow errors. These occur when the
FIFO buffer empties before the device obtains the next DMA request.
Descriptor Errors Internal device error.