3-1
Chapter 3
Checking Status Indicators
Check the LEDs on the ATM link modules or the ARE processor module to verify
that a module is operating after installation.
ARE DS-3, E-3, and SONET/SDH Link Module LEDs
Figure 3-1 shows the LEDs on the ARE E-3 link module. The LEDs are identical
on the ARE DS-3 link module.
Figure 3-1. ARE E-3 Link Module LEDs
Figure 3-2 shows the LEDs on the ARE SONET/SDH link module. The LEDs are
identical on the ARE STS-3/STM-1 SONET/SDH MMF,
STS-3/STM-1 SONET/SDH SMF, and OC-3 link modules.
Note:
We recommend that you issue the
diags
command to the associated slot,
using the Nortel Networks Technician Interface, immediately after you insert a
link module. (Refer to Using Technician Interface Software if you use router
software or Troubleshooting and Testing if you use BayStream software.)
Otherwise, the link module FAIL LED will remain lit, indicating that
diagnostics have not run on the Intelligent Link Interface (ILI). However, even
if you do not issue the
diags
command, the link module initializes and
becomes operational as long as the board functions properly and contains the
correct interface configurations.
FAIL
ARE E-3
MODULE
RESET
ATMC
RESET
SW
LOAD
TEST
RDI
LINK
TX
RX
ALM0003A
Komentáře k této Příručce