Site Manager Parameters
308627-14.20 Rev 00
A-45
Parameter: Poll Interval
Path: Configuration Manager > Protocols > IP > OSPF/MOSPF > Interfaces
Default: 120 seconds
Options: 1 to 2,147,483,647 seconds
Function: Indicates the largest number of seconds allowed between Hello packets sent to
an inactive NBMA neighbor.
Instructions: Either accept the default value of 120 seconds or set this parameter to a slightly
higher number for slower-speed serial lines.
MIB Object ID: 1.3.6.1.4.1.18.3.5.3.2.3.5.1.13
Parameter: Metric Cost
Path: Configuration Manager > Protocols > IP > OSPF/MOSPF > Interfaces
Default: 1
Options: 1 to 65,535
Function: Indicates the cost of using this type of service on this interface. Nortel
Networks suggests the following values for this parameter: for 100 Mb/s or
greater: 1; for Ethernet/802.3: 10; for E1: 48; for T1: 65; for 64 Kb/s: 1562;
for 56 Kb/s: 1785; for 19.2 Kb/s: 5208; for 9.6 Kb/s: 10416. This parameter
allows you to configure preferred paths. If you do want to configure a
preferred path, allow that path to retain the default value of 1 or assign it a
relatively low metric cost. Then, assign the less preferred paths a higher
metric cost value.
Instructions: Either accept the default value, 1, or enter a larger number for a slower path
or a backup route.
MIB Object ID: 1.3.6.1.4.1.18.3.5.3.2.3.5.1.16