286 Maintenance
Enterprise Edge 2.0 Programming Operations Guide P0911588 Issue 01
Eachevent hasa severity number.An“S” preceding this number, “S4” forexample,
may appear in the event message. “S9” is the most severe. If the log is full, new
event messages with a higher severity number replace existing event messages of a
lower severity. For this reason, you should check event messages at regular
intervals. You can then deal with all messages before they are replaced. The time
that the message is recorded is also provided.
Event message information that is specific to Companion components is included
in the Companion event messages (North American systems only) on page 291.
For every event message that you see:
1. Refer to Significant event messages on page 286.
2. Determine if the event caused the system to automatically restart. For more
information, refer to the table on Event Message on page 289.
Significant event messages
The following table lists event messages that are relevant to maintenance activities.
Event message The event message is recorded when…
Evt:210-YYYZ S4 Loopback test YYY on Trunk module Z has been started
Evt:211-YYYZ S4 Loopback test YYY on Trunk module Z has been stopped
Evt:220-3546 S4 the Sys admin log has been cleared by the DN (3546 in this
case)
Evt:221-3546 S4 the Sys test log has been cleared by the DN (3546 in this case)
Evt:222-3546 S5 the DN (3546 in this case) enters the debugging facility that is
password protected
Evt:255 S9 administered mode is notsupported by the module plugged into
the slot
Evt:260-0302 S8 the system takes the access line on port 0302 out of service
because no current was detected
Evt:261-0302 S1 the access line on port 0302 is returned to service after current
was detected (see Evt:260)
Evt:268-07 S8 Dialing filter 07 has lost data due to a fault in the system
memory
Evt:269-3546 S8 the Line/set filter for the DN (3546 in this case) has lost data
due to a fault in the system memory
Evt:299 S1 the system powers up after a power failure
Evt:327 S5 short term alarm threshold has been surpassed in the EE-DTM
Evt:328 S5 short term alarm threshold has been surpassed in the EE-DTM
Evt:329 S5 short term alarm threshold has been surpassed in the EE-DTM
Evt:330 S5 short term alarm threshold has been surpassed in the EE-DTM
Evt:336 S5 long term alarm has been surpassed in the EE-DTM
Evt:373 S5 the system restart diagnostic tool has been activated
Evt:407 S2 there are no more codes for Speed Dial numbers
Evt:408 S2 there is no more memory for Speed Dial codes
Komentáře k této Příručce