Configuring SNMP, BOOTP, DHCP, and RARP Services
1-38
Parameter: Threshold Action
Default: Greaterthan
Options: Greaterthan
| Lessthan
Function: Specifies when the agent generates a threshold event.
Instructions: Select Greaterthan if you want to record threshold events when the value
of the variable is greater than the threshold specified.
Select Lessthan if you want to record threshold events when the value of
the variable is less than the threshold specified.
MIB Object ID: 1.3.6.1.4.1.18.3.3.2.6.2.1.13
Parameter: Threshold Max Successive Alarms
Default: 5
Options: Any integer value
Function: Specifies the maximum number of successive alarms that the agent
generates for this variable. A successive alarm represents two or more
polling periods when the agent generates an alarm as a result of an
exception at the same threshold level.
Instructions: Specify the maximum number of successive alarms. When the agent
exceeds the maximum number of alarms, it marks the threshold as held.
The agent generates no more alarms until the variable either crosses the
threshold at a different level or crosses no threshold for the number of
polling intervals equal to the value of the Threshold HoldDown Intervals
parameter.
MIB Object ID: 1.3.6.1.4.1.18.3.3.2.6.2.1.14