Configuring Dial Services
5-12
Parameter: Circuit Name
Default: None
Options: Any valid demand circuit name
Function: Identifies the name of the demand circuit.
Instructions: Site Manager fills in this name based on the available circuit names. To
modify this parameter, enter a new name to modify and click on Apply.
MIB Object ID: 1.3.6.1.4.1.18.3.3.2.3.1.3
Adding Bandwidth for Dial-on-Demand Lines
If the demand line becomes congested, you can configure the router to bring up a
maximum of three additional dial-up lines to reduce the congestion on a single
demand line.
To do this, you associate a configured bandwidth-on-demand pool with the
demand circuit. To create a bandwidth-on-demand pool, refer to Chapter 4.
To add additional lines to support the demand line:
1. Begin at the Demand Circuits window (Figure 5-2), and click on
BW on Demand.
Site Manager displays the Enter a BOD Pool window (Figure 5-4).
Figure 5-4. Enter a BOD Pool Window