Customizing Line Pools
117353-B Rev. 00
9-33
If you upgrade the central-site router to Version 11.02 (or later) and the
default MRU value of 1500 is taken on one pool (to satisfy 3.522R CLAM
routers or Version 11.02 [or later] routers), you can choose a different default
value (for example, 1590) for a different pool that the Version 11.02 or
pre-3.522R CLAM router dial.
To set the mru parameter, navigate to the dial prompt and enter:
mru <
integer
>
integer can be a value from 1 to 4600
For example:
dial/bri/1/1# mru 1500
Enabling RFC 1661 Compliance
You can use Site Manager to configure a dial circuit to be compliant with Request
for Comment (RFC) 1661.
To enable RFC 1661 compliance, navigate to the dial prompt and enter:
mru-compliance enabled
The default is disabled.
For example:
dial/bri/1/1# mru-compliance enabled