Avaya Configuring Dial Services Uživatelský manuál Strana 262

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 482
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 261
Configuring Dial Services
11-16
117353-B Rev. 00
Modifying the Activation of a Backup Circuit
The primary down time determines how long the router waits before activating a
backup circuit. This delay ensures that the primary has enough time to recover
from any minor failure.
Using the BCC
To set the primary down time parameter, navigate to the backup-circuit prompt
and enter:
primary-down-time
<
integer
>
integer is any number in minutes.
For example:
backup-circuit/10/5/1# primary-down-time 5
Using Site Manager
The primary down time is found on the FR Primary Interface window. To specify
the primary down time, complete the following tasks:
Site Manager Procedure
You do this System responds
1. In the Configuration Manager window,
choose
Dialup
.
The Dialup menu opens.
2. Choose
Backup Circuits
. The Backup Circuits menu opens.
3. Choose
Frame Relay.
The FR Primary Interface Definition
window opens.
4. Set the
Primary Down Time
parameter.
Click on
Help
or see the parameter
description on page A-73.
5. Click on
done
. You return to the Configuration Manager
window.