Chapter 6 Checking the installation prerequisites 73
Installation and Maintenance Guide
Chapter 6
Checking the installation prerequisites
Before you install a main unit or expansion unit, perform the following tasks:
Determine the location for the Avaya Business Communications Manager 50 (Avaya BCM50)
units, telephones, and other equipment based on space and electrical requirements.
Order the required trunks from the central office.
Ensure that you have all the equipment and supplies you need to install the system.
For information about Avaya BCM50 installation prerequisites:
Environmental requirements on page 73
Electrical requirements on page 73
Site telephony wiring requirements on page 74
System equipment, supplies, and tools on page 75
Environmental requirements
Ensure you meet the installation environmental requirements. The installation area must be:
a minimum of 4 m (13 ft.) from equipment such as photocopiers, electrical motors, and other
equipment that produces electromagnetic, radio frequency, and electrostatic interference
within 1.5 m (5 ft.) of a three-wire grounded electrical outlet
clean, dry, well ventilated, and free of traffic and excess dust
within the temperature range of 5°C and 50°C (40°F and 120°F)
from 20% to 80% non condensing relative humidity
structurally strong and with enough space to support the BCM50 units
a minimum of 46 cm (18 in.) from the floor
Electrical requirements
Ensure you meet the following electrical requirements:
Power must be supplied from a non switched, unobstructed outlet within 1.5 m (5 ft.) of the
Avaya BCM50 units.
The supplied power must be a dedicated 110 V to 120 V AC nominal (or 220 V to 240 V AC
nominal), 50 to 60 Hz, 15 A minimum service with a third-wire safety ground. The third-wire
safety ground provides shock protection and prevents electromagnetic interference.
Note: The installation area must be of sufficient height from the floor to prevent water
damage.