78 Chapter 7 Installing the main unit
NN40170-305
For information about installing the main unit:
Unpacking the main unit on page 78
Installing the Avaya BCM50 unit in an equipment rack on page 78
Installing the Avaya BCM50 unit on the wall on page 82
Installing the Avaya BCM50 unit on a desktop or shelf on page 87
Unpacking the main unit
Open the main unit box and check that you have all of the following components:
one main unit (either BCM50, BCM50a, BCM50e, BCM50b, BCM50ba, or BCM50be)
one power supply
one power supply cable
one power supply retention clip
four rubber feet
one screw to secure the RJ-21 telephony connector
one cable tie
a documentation CD
•the Avaya BCM50 Installation Checklist and Quick Start Guide
Visually inspect the components for damage during shipping.
If you find damage, contact your Avaya sales representative.
Installing the Avaya BCM50 unit in an equipment rack
You can install an Avaya Business Communications Manager 50 (Avaya BCM50) main unit in a
standard 19-inch equipment rack along with your other networking and telecommunications
equipment.
To rack-mount an Avaya BCM50 unit, you need the optional rack-mount kit (NT9T6325). This kit
provides the parts to mount up to four BCM50 units into a standard 19-inch equipment rack. The
BCM50 unit mounts into the tabs on the rack-mount shelf. These tabs prevent the unit from sliding
around or falling off the shelf. If the BCM50 system includes additional units, you can mount
another unit onto a second set of tabs on the rack-mount shelf. You can mount any additional units
to tabs on the top of the other units.
If you need to better secure a BCM50 unit, use the screws provided (four per unit) to screw the
BCM50 to the rack. This is a “hardened” installation. For a hardened installation, install only two
units per rack—do not stack the units.
You can also use the optional patch panel to simplify the connections to the BCM50 RJ-21
telephony connector.