Configuring Backup Circuits
114062 Rev. A
9-7
Editing PPP Primary Circuit Definition Parameters
After you designate a primary circuit, Site Manager adds several buttons to the
Primary Circuit Definition window (Apply, Schedule, Phone Out) that allow you
to edit the circuit.
To edit the primary circuit:
1.
Highlight the desired primary circuit and enter new values for the
parameters you want to edit, referring to the following descriptions for
guidelines.
2.
Click on Apply to save your changes.
3.
Click on Done to return to the Configuration Manager window.
Selecting CHAP or PAP for the Primary Circuit
CHAP is the default authentication protocol. To select PAP, you must go to the
PPP Interface List window, select the special line record for dial lines, and specify
PAP in the Local Authentication Protocol parameter. For more information about
PPP and configuring authentication protocols, see
Configuring PPP Services
.