136 Chapter 7 Optional VoIP trunk configurations
P0609327 02
Using CSE 1000 as a gatekeeper
Both the Business Communications Manager and the CSE 1000 must be set to the parameters
described in this section for the gatekeeper to work effectively.
The CSE 1000 GK Admin tool is obtained from http://<Gatekeeper IP>/gk/
.
Before an endpoint registers with the CSE 1000 gatekeeper it must first be added to the gatekeeper
configuration. Before a registered endpoint may make calls, it must have its numbering plan
information assigned within the gatekeeper configuration. Before any of these configuration
changes become part of the gatekeeper active configuration, they must be committed to the active
database. Configuration and activation information is described in the following sections.
Business Communications Manager requirements
Set the Business Communications Manager Local Gateway IP interface to the following:
• Set Call Signaling Method to GatekeeperResolved.
•Set Gatekeeper IP to the IP address at which the CSE 1000 gatekeeper operates.
•Set Alias Names to a single H.323 identifier that is unique across all endpoints registered with
the gatekeeper. For example: “NAME:BCM-OTTAWA”. This H.323 identifier must exactly
match that in the CSE 1000 gatekeeper configuration. This entry is case-sensitive.
Refer to the following sections for detailed information:
• “CSE 1000 configuration, adding an H.323 endpoint”
• “Configuring Codec Compatibility”