Avaya Configuring and Managing Routers with Site Manager Uživatelský manuál Strana 112

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 386
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 111
Configuring and Managing Routers with Site Manager
3-16
309081-14.20 Rev 00
3. Click on the connector for the network interface.
The Add Circuit window opens (Figure 3-8)
.
Figure 3-8. Add Circuit Window
Except for MCT1 and MCE1 connectors, the Configuration Manager
automatically sets all physical layer parameters, that is, the line parameters, to
default values for the type of connector you select. For all LAN connections,
the Configuration Manager also configures the data link layer connection for
the LAN circuit.
4. Accept the default circuit name or type a new one, then click on OK.
See Circuit Naming Conventions on page 3-11
for information about
naming conventions.
5. If the connector supports hardware filters, a window prompts:
Do you want to enable Hardware Filters on this circuit?
Click on OK to enable hardware filters. Otherwise, click on Cancel to exit the
window. You return to the Add Circuit window.
6. Click on OK.
Go to the next section to add protocols.