Avaya Using Technician Interface Scripts Uživatelský manuál Strana 287

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 849
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 286
show dsx3
117380-A Rev. A 2-243
current
[
<circuit name>
]
Displays the general circuit information in addition to current DS-3/E-3 information for
the specified circuit or for all circuits. For more information on column definitions, see the
ccts command.
The table displays the following information:
General Circuit Information
Circuit Name Name of the circuit associated with this line.
Index Line and line level identifier.
Sec into Interval The number of seconds into the current 15-minute interval.
# of Intervals The number of complete 15-minute intervals.
Line Coding The line coding on this circuit. The line coding options are
B3ZS
HDB3
Line Type The line type of this circuit. The options are
DS3_M23 (ANSI T1.107-1988)
DS3_Cbit (ANSI T1.107a-1989)
E3_framed (CCITT G.751)
E3_plcp (ETSI T/NA[91]18)
Status The line status of the interface. The possible status variables are
NoAlarm - no alarm present
RRAI - receiving yellow remote alarm indication
TRAI -- transmitting yellow remote alarm indication
RAIS - receiving Alarm Indications Signal (AIS) failure state
TAIS - transmitting AIS failure state
LOF - receiving Loss of Frame (LOF) failure state
LOS - receiving Loss of Signal (LOS) failure state
Loopback
- looping the received signal
TestCode - receiving a test pattern
LowSignal - low signal
Zobrazit stránku 286