System Administration
8-27
We recommend that you issue the diags command to the associated slot
immediately after you hot-swap a board. Otherwise, the DIAG LED on the front
panel and LED 8 on the FRE module remain on, indicating that diagnostics have
not been run on the ILI. (Refer to the Installing and Maintaining BN Routers
manual for more information.) If the board is functional, and you do not issue the
diags command, the processor module automatically boots, loads the
configuration, starts the router software services, and operates normally, although
the DIAGS LED remains lit.
When you issue the
diags or diags
<slot_no.>
commands from a local console
rather than from a Telnet session, the results depend on
The slot number you designate in the command line
The slot number from which you issue the command
The model of Bay Networks router
The type of router (single-slot or multislot)
Based on these variables, the router system or slot performs a restart, a warm-
boot, or a cold-boot operation. The following table describes the different
responses: