Configuring MCE1 and MCT1 Services
308648-14.00 Rev 00
7-11
Using Site Manager
See the Setup Alarm Threshold parameter on page A-26 for information.
Setting the Alarm Threshold Clear Time
By default, the clear time for performance-failure conditions is 2 seconds.
If the defect or anomaly clears in this time interval, MCE1 records a
performance-cleared condition and logs an event message. Change the alarm
threshold clear time to any value from 2 to 10 seconds for this MCE1 interface.
Using the BCC
To change the alarm threshold clear time, navigate to the mce1 prompt (for
example,
stack
;
mce1/1/2/1
) and type:
clear-alarm-threshold
integer
For example:
mce1/1/2/1#
clear-alarm-threshold 3
Using Site Manager
See the Clear Alarm Threshold parameter on page A-27 for information.
Enabling or Disabling the International Bit
By default, the MCE1 interface does not use the international bit in E1 frames.
Using the BCC
To enable or disable the international bit, navigate to the mce1 prompt (for
example,
stack
;
mce1/1/2/1
) and type:
international-bit
variable
For example:
mce1/1/2/1#
international-bit enabled
Using Site Manager
See the International Bit parameter on page A-27 for information.