Site Manager Parameters
308648-14.00 Rev 00
A-9
Parameter: 64K Transmit Monitor
Path: COM Connector > Edit DSU/CSU > Edit DSU CSU Parameters
Default: Disabled
Options: Enabled
|
Disabled
Function: Valid only in 64K Clear Channel mode (Option Mode set to CC-64KBPS).
When enabled, the parameter suppresses data to prevent unintended duplication
of a network control code. For example, user data that happens to include the
text of a loopback control code could place the remote end of the connection
into a loop.
Instructions: Specify Enabled to monitor and suppress user data; keep the default, Disabled,
to allow all data.
MIB Object ID: 1.3.6.1.4.1.18.3.4.30.1.1.9
Parameter: V.54 Loopback
Path: COM Connector > Edit DSU/CSU > Edit DSU CSU Parameters
Default: NO LOOP
Options: NO LOOP
|
ANALOG
|
DIGITAL
|
REM DIGITAL
|
REM DIG/ PATTERN
|
ANALOG/ PATTERN
|
PATTERN-2047
Function: Configures a V.54 loopback test state within the DSU/CSU.
Note that selecting a loopback test state disrupts user data transmission through
the DSU/CSU for the period specified by the V.54 Timer parameter.
Instructions: Select a test state or keep the default, NO LOOP.
MIB Object ID: 1.3.6.1.4.1.18.3.4.30.1.1.12