Configuring MCE1 and MCT1 Services
308648-14.00 Rev 00
7-63
To run MCE1 or MCT1 port tests, complete the following tasks.
See Table 7-21
for the list of BERT test commands you can send on any MCT1 or
MCE1 port. See Table 7-22
for the list of loopback commands you can send on an
MCT1 port only.
Setting Logical Line Test Parameters
On DMCT1 net modules, QMCT1 link modules, and QMCT1 w/ DS0A link
modules only, you can test an individual logical line (DS0 group) associated with
a port.
Site Manager Procedure
You do this System responds
1. Set the test parameters in the Port Actions
window. See “Setting Port Test
Parameters” earlier in this chapter.
2. Click on
Apply
. Site Manager sets the parameters to the
values you specified.
3. To start a test, click on the appropriate
Send
command.
Site Manager performs the test you
selected.
4. Repeat step 3
for each test you want to
run.
5. Click on
Done
. The MCE1 or MCT1 Port Parameters
window opens.
Komentáře k této Příručce