Configuring WAN Line Services
A-40
308648-14.00 Rev 00
Parameter: CRC Size
Path: Configured MCE1 or MCT1 Connector > MCE1 or MCT1 Logical Lines
Default: 16 bit CRC
Options: 32 bit CRC
|
16 bit CRC
Function: Specifies the CRC type. With 16-bit CRC, the router appends a 16-bit CRC to
the transmitted frames and performs a 16-bit CRC on received frames. With
32-bit CRC, the router appends a 32-bit CRC to transmitted frames and
performs a 32-bit CRC on received frames.
Instructions: Set the CRC size.
MIB Object ID: 1.3.6.1.4.1.18.3.4.9.6.1.20
Parameter: MTU Size (bytes)
Path: Configured MCE1 or MCT1 Connector > MCE1 or MCT1 Logical Lines
Default: 1600 bytes
Options: 3 to 4608 bytes
Function: Specifies the transmit/receive buffer size (MTU) to configure the largest frame
that the router can transmit or receive over this port. The router discards frames
larger than this value.
Instructions: Specify a value in the range 3 to 4608 bytes.
MIB Object ID: 1.3.6.1.4.1.18.3.4.9.6.1.55
Parameter: Remote Loopback Detection
Path: Configured MCE1 or MCT1 Connector > MCE1 or MCT1 Logical Lines
Default: Disable
Options: Enable
|
Disable
Function: Enables or disables detection of the driver’s BofL packets, provided that you set
the Breath of Life (BofL) Enable/Disable parameter to Enable. If you select
Enable and put the line into loopback mode, the downstream driver will bring
down the interface when it detects its BofL packets.
Instructions: Select Enable or Disable.
MIB Object ID: 1.3.6.1.4.1.18.3.4.9.6.1.56