Configuring FT1 Services
308648-14.00 Rev 00
8-11
Using Site Manager
See the Clear Alarm Threshold (seconds) parameter on page A-47 for
information.
Setting the FDL Mode for ESF Line Types
The FT1 interface selects a facility data link (FDL) mode only when the Line Type
parameter is configured as ESF (see “Setting the FT1 Line Type” on page 8-7
).
Select one of the following ESF line types:
Using the BCC
To set the FDL mode, navigate to the ft1 prompt (for example,
box
;
ft1/1/1
) and
type:
facilities-data-link
integer
For example:
ft1/1/1#
facilities-data-link att-54016
Using Site Manager
See the FDL Configuration parameter on page A-47 for information.
Table 8-6. ESF Line Types
BCC Option Site Manager Option Description
ansi-403 ANSI 403 The default; conforms to the 1989 ANSI
T1.403 specification (
Carrier-to-Customer
Installation DSI Metallic Interface)
att-54016 AT&T 54016 Conforms to the 1989 AT&T specification
(
Requirements for Interfacing Digital
Terminal Equipment to Services Employing
the Extended Superframe Format
)
none None Disables the FDL mode