Configuring MCE1 and MCT1 Services
308648-14.00 Rev 00
7-39
You can edit the logical line parameters from the logical-line/mce1-121-1 prompt.
See the following sections for information about editing logical line parameters.
Using Site Manager
To edit parameters for a logical line, complete the following tasks.
Enabling or Disabling the Logical Line
The logical line is enabled by default. You can disable or reenable each logical
line.
Using the BCC
To enable or disable the logical line, navigate to the logical-line prompt (for
example,
stack
;
mce1/1/2/1
;
logical-line/mce1-121-1
) and type:
state
variable
For example
logical-line/mce1-121-1#
state disabled
Using Site Manager
See the Enable/Disable parameter on page A-36 for information.
Site Manager Procedure
You do this System responds
1. In the MCE1 or MCT1 Logical Lines
window, select the line and circuit name
from the logical lines list.
Site Manager displays the circuit’s
parameters.
2. Edit the parameters.
3. Click on
Apply
.