Using Technician Interface Scripts
2-90
receive errors
[
circuit
<circuit name>
]
Displays receive error information for the specified circuit or for all circuits:
For more information on column definitions, see the
alerts command.
Sample Display – show atm line receive errors
ATM Module Receive Errors:
--------------------------
Address Rcv Q Rcv Q Rcv Q
Dropped Translation Full Write Empty
Slot Conn Circuit Cells Errors Errors Errors Errors
---- ---- -------- ---------- ----------- ---------- ---------- ----------
4 1 A41 0 0 0 0 0
5 1 A51 0 0 0 0 0
2 entries in table.
Dropped Cells Number of cells received at the transceiver receive interface that
have been discarded.
Address Translation Errors Number of address translation errors received.
Rcv Q Full Errors Number of full queue errors received.
Rcv Q Write Errors Number of write queue errors received. Write failures occur when
the SAR device tries to write to an already full queue.
Rcv Q Empty Errors Number of empty queue errors received. Empty errors occur when
the SAR device has no place to put the data it has received.