stats clnp
Displays statistics for the ConnectionLess Network Protocol (CLNP) packets on each OSI
circuit. The table includes the number of CLNP packets received and forwarded, the
number of Echo Replies received (Rx) and sent (Tx) and the number of Echo Requests
received (Rx) and sent (Tx).
Sample Display – show osi stats clnp
OSI Circuit CLNP Statistics
---------------------------
CLNP CLNP Rx Echo Rx Echo Tx Echo Tx Echo
Circuit Received Forwarded Rep Req Rep Req
-------- ------------ ------------ -------- -------- -------- --------
E31 0 0 0 0 0 0
E32 0 0 0 0 0 0
O41 0 0 0 0 0 0
stats errors
Displays error statistics for each OSI circuit. The table includes the following information:
Init Failures Number of times this circuit failed to initialize.
Rejected Adjs Number of adjacencies rejected on this circuit.
Bad LSPs Number of bad link state packets (LSPs) received on this circuit.
Bad Snps Number of bad Sequence Number PDUs received on this circuit.
Bad Eshs Number of bad End System hellos received on this circuit.
Bad L1Iihs Number of bad Level 1 IS - IS hellos received on this circuit.
Bad L2Iihs Number of bad Level 2 IS - IS hellos received on this circuit.